by Kohler

Kohler 26RCA

26 kW standby generator

Key specifications

Rated output, propane
26 kW
Rated output, natural gas
24 kW
Fuel
Dual fuel (NG / LP)
Phase
Single-phase
Transfer switch
Not included
MSRP (starting)
$7,445
Dimensions
47 x 26.0 x 32.3 in
Shipping weight
670 lb
Engine displacement
999 cc
Sound, running (23 ft)
67 dB
Sound, exercise (23 ft)
56 dB
Warranty
5 years

Unverifiable specs are omitted, not estimated. See sources below for what we can defend.

Fuel use

FuelHalf loadFull load
Propane2.32 gal/hr3.53 gal/hr
Natural gas180 ft³/hr290 ft³/hr

On propane, a 500-gallon tank filled to 80% holds about 400 gallons. That runs the Kohler 26RCA for about 172 hours (7.2 days) nonstop at half load, or about 113 hours (4.7 days) at full load. See how much propane a generator uses for other tank sizes.

On natural gas, the gas line and meter have to deliver the full-load figure, 290 ft³/hr, even if the generator rarely runs that hard. Installers size the pipe to it.

Kohler publishes propane use in cubic feet per hour. Gallons are converted at Kohler's 2,500 Btu per cubic foot and the EIA's 91,452 Btu per gallon.

Sources

Every spec above traces back to one of these citations.